100% is full data coverage, 0% is no data
Elec |
Heat |
Flow |
Return |
Outside |
Information about this system.
Overview | ||
---|---|---|
Location | West Oxfordshire | |
Installer | Octopus Energy Services | |
Installer URL | https://octopus.energy/get-a-heat-pump/ | |
Training | ||
Heat Geek Mastery | ||
Ultimate Renewables Pro | ||
Heating Academy Hydronics | ||
Learn more | ||
BetaTalk | 0 | |
YouTube | ||
Heat pump | ||
Heat pump type | Air Source | |
Heat pump make & model | Daikin Altherma 3 | |
Heat pump output | 6 kW | |
Refrigerant | R32 | |
Heat pump has backup heater installed and in use | ||
Space heating | ||
Design flow temperature | 50 °C | |
Outside design temperature | -2.4 °C | |
Weather compensation curve | 0 | |
Space heat control type | Weather compensation with a little room influence | |
Number of zones | 1 | |
New radiators | ||
Old radiators | ||
Fan coil radiators | ||
Underfloor heating | ||
Hydraulic seperation | None | |
Volumiser | ||
Hot water | ||
Hot water method | Cylinder with coil | |
Cylinder volume | 250 litres | |
Coil or heat exchanger area | 0 m² | |
DHW target temperature | 46 °C | |
DHW control type | Automatic top up of tank if temperature drops by 6-10C | |
Legionella frequency | Disabled | |
Misc | ||
Freeze protection | Anti-freeze valves | |
Property | ||
Heat loss at design temperature | 5.6 kW @ -3°C | |
Property type | Semi-detached | |
Floor area | 131 m² | |
Age | 1983 to 2011 | |
Insulation level | Fully insulated walls, floors and loft | |
Assessed space heat demand | 9436 kWh/year | |
Assessed water heat demand | 2881 kWh/year | |
Generation | ||
Annual solar PV generation | 0 kWh | |
Solar PV self consumption | 0 % | |
Solar PV divert to hot water immersion | ||
Battery storage capacity | 13 kWh | |
Metering | ||
MID Metering | ||
Electric meter | SDM120 Modbus/MBUS Single Phase (class 1) | |
Heat meter | Kamstrup heat meter (class 2) | |
Includes primary circulation pump | ||
Includes indoor controller or other controls | ||
Includes indoor temperature sensing | ||
Data issue flag | ||
Data issue flag note | ||
Notes | ||
Any other notes or comments | Modulation by Madoka thermostat disabled. Overshoot set to 3C to reduce cycling (emitters set to UFH to "unlock" overshoot value). System design temp was 50C @ -2.4C, WDC is now 36C@-2C -> 34C@10C. Home Assistant automations used to reduce hysteresis to ± 0.5C, trigger DHW when tank temperature drops below 35C (in off-peak period or when sufficient home-battery capacity) & more dynamic modulation of the flow temperature based on both outdoor and indoor temperature. System set to "Most Quiet" at all times. |