Data Coverage

100% is full data coverage, 0% is no data

Elec
Heat
Flow
Return
Outside

Information about this system.

Overview
Location Llanberis, Gwynedd
Installer Trystan Lea (self-install)
Installer URL https://trystanlea.org.uk
Training
Heat Geek Mastery
Ultimate Renewables Pro
Heating Academy Hydronics
Learn more
BetaTalk
YouTube https://www.youtube.com/watch?v=m2-_x0XZUSM
Heat pump
Heat pump type Air Source
Heat pump make & model Mitsubishi Ecodan
Heat pump output 5 kW
Refrigerant R410A
Heat pump has backup heater installed and in use
Space heating
Design flow temperature 45 °C
Outside design temperature -3 °C
Weather compensation curve 0
Space heat control type Manual flow temperature control
Number of zones 1
New radiators
Old radiators
Fan coil radiators
Underfloor heating
Hydraulic seperation None
Volumiser
Hot water
Hot water method Cylinder with coil
Cylinder volume 150 litres
Coil or heat exchanger area 3
DHW target temperature 42 °C
DHW control type Twice daily scheduled heat up of tank
Legionella frequency Disabled
Misc
Freeze protection Central heat pump water circulation
Property
Heat loss at design temperature 4 kW @ -3°C
Property type Mid-terrace
Floor area 77
Age Pre-1900
Insulation level Solid walls
Assessed space heat demand 8000 kWh/year
Assessed water heat demand 2000 kWh/year
Generation
Annual solar PV generation 0 kWh
Solar PV self consumption 0 %
Solar PV divert to hot water immersion
Battery storage capacity 0 kWh
Metering
MID Metering
Electric meter SDM120 Modbus/MBUS Single Phase (class 1)
Heat meter Sontex heat meter (class 2)
Includes primary circulation pump
Includes indoor controller or other controls
Includes indoor temperature sensing
Data issue flag
Data issue flag note
Notes
Any other notes or comments