Data Coverage

100% is full data coverage, 0% is no data

Elec
Heat
Flow
Return
Outside

Information about this system.

Overview
Location Wrexham
Installer AIR2HEAT LTD
Installer URL https://www.air2heat.co.uk
Training
Heat Geek Mastery
Ultimate Renewables Pro
Heating Academy Hydronics
Learn more
BetaTalk
YouTube
Heat pump
Heat pump type Air Source
Heat pump make & model Vaillant Arotherm+
Heat pump output 7 kW
Refrigerant R290
Heat pump has backup heater installed and in use
Space heating
Design flow temperature 40 °C
Outside design temperature -3 °C
Weather compensation curve 0.7
Space heat control type Pure weather compensation, no room influence
Number of zones 1
New radiators
Old radiators
Fan coil radiators
Underfloor heating
Hydraulic seperation None
Volumiser
Hot water
Hot water method Phase change store
DHW target temperature 70 °C
DHW control type Daily scheduled heat up of tank
Misc
Freeze protection Anti-freeze valves
Property
Heat loss at design temperature 7.8 kW @ -3°C
Property type Detached
Floor area 99
Age 1940 to 1982
Insulation level Cavity wall, plus some loft insulation
Assessed space heat demand 16479 kWh/year
Assessed water heat demand 0 kWh/year
Generation
Annual solar PV generation 0 kWh
Solar PV self consumption 0 %
Solar PV divert to hot water immersion
Battery storage capacity 0 kWh
Metering
MID Metering
Electric meter SDM120 Modbus/MBUS Single Phase (class 1)
Heat meter Sontex heat meter (class 2)
Includes primary circulation pump
Includes indoor controller or other controls
Includes indoor temperature sensing
Data issue flag
Data issue flag note
Notes
Any other notes or comments Sunamp Thermino xPlus 210