100% is full data coverage, 0% is no data
Elec |
Heat |
Flow |
Return |
Outside |
Information about this system.
Overview | ||
---|---|---|
Location | Brynrefail, Gwynedd | |
Installer | Flam Eryri | |
Installer URL | https://www.fflameryri.co.uk/ | |
Training | ||
Heat Geek Mastery | ||
Ultimate Renewables Pro | ||
Heating Academy Hydronics | ||
Learn more | ||
BetaTalk | 0 | |
YouTube | ||
Heat pump | ||
Heat pump type | Air Source | |
Heat pump make & model | NIBE F2040 | |
Heat pump output | 12 kW | |
Refrigerant | R410A | |
Heat pump has backup heater installed and in use | ||
Space heating | ||
Design flow temperature | 50 °C | |
Outside design temperature | -3 °C | |
Weather compensation curve | 0 | |
Space heat control type | Weather compensation with simple set point control | |
Number of zones | 2 | |
New radiators | ||
Old radiators | ||
Fan coil radiators | ||
Underfloor heating | ||
Hydraulic seperation | None | |
Volumiser | ||
Hot water | ||
Hot water method | Cylinder with coil | |
Cylinder volume | 300 litres | |
Coil or heat exchanger area | 0 m² | |
DHW target temperature | 45 °C | |
DHW control type | Automatic top up of tank if temperature drops by 6-10C | |
Legionella frequency | Weekly | |
Legionella target temperature | 0 °C | |
Legionella cycle uses immersion heater | ||
Misc | ||
Freeze protection | Central heat pump water circulation | |
Property | ||
Heat loss at design temperature | 9.6 kW @ -3°C | |
Property type | Semi-detached | |
Floor area | 141 m² | |
Age | Pre-1900 | |
Insulation level | Cavity wall, plus some loft insulation | |
Assessed space heat demand | 6000 kWh/year | |
Assessed water heat demand | 0 kWh/year | |
Generation | ||
Annual solar PV generation | 0 kWh | |
Solar PV self consumption | 0 % | |
Solar PV divert to hot water immersion | ||
Battery storage capacity | 0 kWh | |
Metering | ||
MID Metering | ||
Electric meter | OpenEnergyMonitor EmonPi v2, EmonTx4 or newer | |
Heat meter | Sontex heat meter (class 2) | |
Includes DHW immersion heater | ||
Includes primary circulation pump | ||
Includes indoor controller or other controls | ||
Includes indoor temperature sensing | ||
Data issue flag | ||
Data issue flag note | ||
Notes | ||
Any other notes or comments | Converted solid stone chapel. Timber suspended UFH (no slab) on both floors, fully-open loop |