Data Coverage

100% is full data coverage, 0% is no data

Elec
Heat
Flow
Return
Outside

Information about this system.

Overview
Location Brynrefail, Gwynedd
Installer Flam Eryri
Installer URL https://www.fflameryri.co.uk/
Training
Heat Geek Mastery
Ultimate Renewables Pro
Heating Academy Hydronics
Learn more
BetaTalk 0
YouTube
Heat pump
Heat pump type Air Source
Heat pump make & model NIBE F2040
Heat pump output 12 kW
Refrigerant R410A
Heat pump has backup heater installed and in use
Space heating
Design flow temperature 50 °C
Outside design temperature -3 °C
Weather compensation curve 0
Space heat control type Weather compensation with simple set point control
Number of zones 2
New radiators
Old radiators
Fan coil radiators
Underfloor heating
Hydraulic seperation None
Volumiser
Hot water
Hot water method Cylinder with coil
Cylinder volume 300 litres
Coil or heat exchanger area 0
DHW target temperature 45 °C
DHW control type Automatic top up of tank if temperature drops by 6-10C
Legionella frequency Weekly
Legionella target temperature 0 °C
Legionella cycle uses immersion heater
Misc
Freeze protection Central heat pump water circulation
Property
Heat loss at design temperature 9.6 kW @ -3°C
Property type Semi-detached
Floor area 141
Age Pre-1900
Insulation level Cavity wall, plus some loft insulation
Assessed space heat demand 6000 kWh/year
Assessed water heat demand 0 kWh/year
Generation
Annual solar PV generation 0 kWh
Solar PV self consumption 0 %
Solar PV divert to hot water immersion
Battery storage capacity 0 kWh
Metering
MID Metering
Electric meter OpenEnergyMonitor EmonPi v2, EmonTx4 or newer
Heat meter Sontex heat meter (class 2)
Includes DHW immersion heater
Includes primary circulation pump
Includes indoor controller or other controls
Includes indoor temperature sensing
Data issue flag
Data issue flag note
Notes
Any other notes or comments Converted solid stone chapel. Timber suspended UFH (no slab) on both floors, fully-open loop